Dwelling Required Branch Circuits: NEC 210.11(C) Checklist

/ 5 min read / By CircuitDrill

Before you size a service or run a single cable in a house, you need to know which branch circuits the code says must exist. NEC 210.11(C) lists the dwelling unit circuits that are required in addition to the general lighting and receptacle circuits. This is a checklist article: read it once, then use the list to test yourself on kitchen, laundry, bathroom and garage circuits.

The short version

AreaSectionWhat is required
Kitchen, pantry, breakfast room, dining room210.11(C)(1)At least two 20-ampere small-appliance branch circuits
Laundry210.11(C)(2)At least one 20-ampere branch circuit for the laundry receptacles
Bathrooms210.11(C)(3)At least one 20-ampere branch circuit for the bathroom receptacles
Garage210.11(C)(4)A dedicated 20-ampere, 120-volt circuit for the garage receptacles (as summarized in one county guide)

These items come from three building-department style documents that summarize the code: the Jefferson County, Colorado electrical wiring guide (2023 NEC), the City of Saint Paul dwelling rough-in checklist (2020 NEC), and the New York Electrical Inspection Agency 2023 residential summary. The kitchen, laundry and bathroom items agree across the 2020 and 2023 editions in those documents.

Checklist item 1: kitchen small-appliance circuits

  • You need a minimum of two 20-ampere small-appliance branch circuits.
  • They serve receptacles for small appliances in the kitchen, pantry, breakfast room and dining room, including refrigeration equipment (Jefferson County guide).
  • Kitchen countertop receptacles must be supplied by at least two small-appliance circuits (210.52(B)(3), per the Saint Paul checklist).
  • These circuits cannot supply receptacles outside those areas, and lighting outlets are not allowed on them (Jefferson County guide). The Saint Paul checklist quotes the rule as: the small-appliance branch circuits shall have no other outlets.

A common exam trap is to put the kitchen lights on one of these circuits to "balance the load." That breaks the no-other-outlets rule. Lighting goes on a separate circuit.

Checklist item 2: laundry circuit

  • At least one 20-ampere branch circuit for the laundry receptacles.
  • It serves the laundry area only, with no lighting outlets (Jefferson County guide). The New York summary describes it as not feeding other outlets.

Do not combine the laundry circuit with the kitchen small-appliance circuits. They are separate required circuits.

Checklist item 3: bathroom circuit

The bathroom rule has two shapes, and the exam likes to test the difference. According to the Jefferson County guide, one 20-ampere circuit can serve all bathroom receptacles in the dwelling, provided it serves no other receptacle outlets or equipment. Or, a single dedicated circuit can serve all the outlets and equipment (receptacles, lights, fans) in one bathroom, provided it serves nothing else. The New York summary says the same thing in shorter form: if the circuit serves a single bathroom, other equipment in that bathroom may be supplied as the NEC permits.

  • Bathroom receptacles: at least one 20-ampere circuit.
  • A receptacle is needed within 3 feet of each basin (210.52(D)).
  • Do not run a bedroom light or a hallway receptacle on the bathroom circuit.

Checklist item 4: garage circuit

The Jefferson County guide lists a dedicated 120-volt, 20-ampere circuit for garage receptacles under 210.11(C)(4), with one receptacle per vehicle bay and a limit on mounting height under 210.52(G)(1). The New York summary page did not include a garage item, so confirm this one in the edition your state has adopted before you answer a question about it.

Protection is a separate question

Having the right number of circuits does not settle the shock and arc protection requirements. The New York summary lists GFCI protection (210.8(A)) for new or changed receptacles in bathrooms, garages, kitchens, laundry areas and areas with sinks, and AFCI protection (210.12(A)) for rooms such as kitchens and laundry rooms. The Jefferson County guide notes that bathrooms and garages are exempt from the general AFCI requirement in 210.12(A). Those rules change from edition to edition, so read the exact text for your code cycle. For more on that topic, see the OhmPrep guide on GFCI versus AFCI.

Quick self-check

  1. How many 20-ampere small-appliance circuits are required at a minimum? Two.
  2. Can the kitchen lights share a small-appliance circuit? No. These circuits have no other outlets.
  3. Can one 20-ampere circuit serve the lights, fan and receptacle of a single bathroom? Yes, if it serves nothing else.
  4. Can the laundry circuit feed a nearby hallway receptacle? No.

How to use this list on exam day

When a question describes a new dwelling and asks which circuits are required, go area by area. Kitchen first: two small-appliance circuits. Laundry next: one circuit. Bathroom: one circuit, and read carefully whether the question describes one bathroom or several. Then ask whether the house has a garage and which edition the question uses. Write each circuit down as you go, and cross-check that no required circuit is carrying a lighting outlet it should not carry. Most lost points on this topic come from counting a shared circuit as two, or from adding a light to a circuit that must have no other outlets.

Read the real code

Local amendments and the adopted edition matter. Use your own code book and ask the authority having jurisdiction (AHJ) before you design or install anything. The National Fire Protection Association publishes NFPA 70 with free online access at nfpa.org. OhmPrep is an independent study tool and is not affiliated with NFPA or the NEC.

Keep practicing

Pair this checklist with the guide to the 12-foot receptacle rule, and try more exam-style problems in the OhmPrep course.

Frequently asked questions

How many small-appliance branch circuits does a dwelling kitchen need?

At least two 20-ampere small-appliance branch circuits, serving the kitchen, pantry, breakfast room and dining room receptacles under 210.11(C)(1). These circuits have no other outlets.

Does a dwelling need a separate laundry circuit?

Yes. 210.11(C)(2) calls for at least one 20-ampere branch circuit for the laundry receptacles, separate from the small-appliance circuits.

Can bathroom lights and receptacles share one circuit?

Under 210.11(C)(3), one 20-ampere circuit can serve all the outlets in a single bathroom if it serves nothing else. Otherwise a bathroom receptacle circuit cannot serve other outlets. Check your adopted edition.

Is a garage circuit required?

One county guide lists a dedicated 20-ampere, 120-volt garage receptacle circuit under 210.11(C)(4). Confirm the requirement in the edition your state has adopted.